Skip to main content Link Menu Expand (external link) Document Search Copy Copied

boltPost Bolts Strength

Table of contents

About

The “Bolts Result” object adds the post processing features to Bolts Pretension, Simplified Bolts and Advanced Bolts load objects. This result object will extract all relevant information from the selected bolt joint group and create a results summary listing. It also includes the Eurocode 3 evaluation of the bolt results.

about

Usage

Bolt result objects for all bolts in the Child Setup, Bolts Group or a selected Bolt object can be added using the context action “Add Bolts Strength”.

add_bolts_strength

Inputs to define the Bolts Strength are defined in the table below.
If selecting Bolt Code additional properties are visible and described in the Design Codes section.

code

Geometry  
Scoping Method All Bodies (Default)/Geometry Selection/Named Selection
Geometry Faces/Bodies to display results on (i).
Bolt Geometry  
Bolt Object Select a Bolt object from the list (ii).
Pretension Force, Fp Nominal applied pretension force (read only)
Nominal Diameter, d Shaft nominal diameter used in evaluation (can be changed).
Nominal Diameter Length Length of unthreaded bolt shaft with nominal diameter (can be changed).
Stress Diameter, ds Shaft stress diameter used in evaluation (can be changed).
Hole Diameter, d0 Identified hole diameter (can be changed).
Head Diameter, dm Head diameter (can be changed).
Bolt Evaluation  
Bolt Code None/Eurocode 3 (Default)/AISC
Bolt Result  
Result Item Select a Result Item to display.
Result Tolerance Factor Value between 0 (Default) to 1 to filter out result values.
Result Averaging Display results for each bolt Individual (Default) or as a Group average.
Result Location Head/Mid (Default)/Thread Location of evaluation section.
Calculate Time History No/Yes (Default)
Scale Factor Value Scale factor on the calculated loads, e.g. load safety factor (iii).
Definition  
By Time (Default)/Result Set/Maximum Over Time/Time Of Maximum (standard Mechanical feature) (iv).
Display Time Load step time for results evaluation (v).

Note that the Analysis Settings/Output Controls “Nodal Forces = Yes” must be set in order for post processing to work. When adding the first bolt object this setting is automatically set to “Yes”.

(i) Geometry

To limit post processing to specific bolts in the group edit the geometry scoping of faces or bodies. The node numbers from the selected bolt object will be compared with the node numbers in the selection and results will only be plotted for nodes/bolts that are scooped in the selection.

(ii) Bolt Object

To avoid duplicate names the bolt object Id number is appended to the name. The bolt object may be a Bolts Pretension, Simplified Bolts or Advanced Bolts. When selecting a bolt object the bolt dimensions are retrieved.

(iii) Scale Factor Value

In a Random Vibration analysis this sets the probability of the results (1: 68.269%, 2: 95.45%, 3: 99.73%).

(iv) By

You may use Maximum Over Time to get the worst case from all steps. In addition, the Graph displays the time history of min and max for the selected result.

(v) Display Time

You may only use time steps where there are results saved, see the graph and tabular data window for load steps to use.

Result Items

The bolt pretension force and geometric dimensions are used in the code evaluation.

Result Item Description
Normal Force Axial force in bolt shaft, Fn (i)
Shear Force Shear force sum in bolt shaft, Fv
Bending Moment Bending moment sum in bolt shaft, Mb
Normal Stress Axial stress in bolts shaft, σn = Fn/As where As = πd2/4
Shear Stress Shear stress in bolt shaft, τv = Fv/As
Bending Stress Bending stress in bolt shaft, σb = Mb/Ws where Ws = πd3/32
Structural Stress Normal + Bending stress in a bolt shaft, σs = σn + σb
Adjustment Total elongation of bolt joint (displacement of pretension element) δAdj
Pretension change Change of axial force relative to pretension force, Fdiff = Fn - Fp
Head Contact Pressure Average head contact pressure, Phead = Ft/Anet where Anet = π(dm2-d02)/4 (ii)
Contact Slip Force Average contact shear force per contact plane, FsEd
Contact Normal Force Average contact normal force per contact plane, FcEd

(i) Normal Force

If using Pretension Type “MPC184” the Normal Force at the “Load Step Apply” will not be listed or plotted in the bolt result. When extracting results for MPC184 the joint constraint forces are used in order to get forces in the bolt local system. Therefore the normal force will only be visible in listing and plotting at the “Load Step Lock” or later. MPC184 should only be used when large deflections or rotations are present in the model.

(ii) Tension Force

The Tension Force used in Head Contact Pressure is the positive part of Normal Force, Ft = max(0, Fn).

Result Location

The forces and moments are extracted at the mid of the bolt shaft (at the pretension section).
If the Result Location is “Head” or “Thread” the bending moment, Mb, is derived at the corresponding location. (All other section forces are constant along the bolt shaft.)
If the Nominal Diameter Length is greater than zero the Nominal Diameter, d, is used as the Stress Diameter, ds, for “Head” location.
If the Nominal Diameter Length is greater than half the free bolt shaft length the Nominal Diameter, d, is used as the Stress Diameter, ds, for “Mid” location (as in the figure below).
At the “Thread” location the Stress Diameter, ds, is always used.

location

Output

The selected “Result Item” at the Result Location is displayed on the geometry.
For a Bolt Group Pretension object, the result is displayed on the bolt shaft for each bolt.
For a Simplified Bolts or Advanced Bolts the results are presented at the bolt hole (solid parts) or at the bolt head contact (shell parts) for each bolt.
about

The Bolts Result object writes a property and result csv files to the solver files directory of the analysis. These files are used by the Bolt Report features and can easily be imported to Word or Excel.
You may display the output using the Worksheet Preview feature. If Result Averaging = “Group” is selected the group average is listed on the first line with Bolt Id = “0”. The Group average is useful for post processing e.g. the risk for global slipping in a bolt group, i.e. the average slip utilization of all bolts is greater than 1.

Graphics

The bolt geometry can be visualized on the results using the Bolt Settings property “Show Geometry on Results = Yes”. The translucency can also be set for the results using the property “Result Translucency”.

If the Result Item is “Shear Force” or “Contact Slip Force” a vector is displayed at the bolt shaft mid when selecting an evaluated result.
The reaction force vector direction relates to the bolt head part or the first contact side part (if there are multiple contacts in the joint). The length of the vector is proportional to the individual magnitude of the force. For “Grouped results” or “Maximum over Time” no vector is displayed.

vector

Derived bolt results

From the results listing additional bolt joint post processing can be done, e.g. to study embedding influence on bolt pretension or the relation in stiffness between bolt shaft and support.

stiffnessCalc

Output csv files

When post processing a bolt group for the first time the bolt index, coordinates, section forces and moments are extracted for all load steps and written to csv file in the sub folder “BoltToolkit” in the solver files directory (in the solution units). This file is used when post processing the bolts.
The bolt coordinate system can be displayed in the graphics using the Bolt Settings option “Show Bolt Coordinate System = Yes”.

boltRes

The contact slip and normal force is dependent on the Contact Slip Radius.

Contact slip and normal force

The average slip and normal force per contact plane is derived from contact pairs along the bolt shaft within the “contact slip radius”, rslip, the first time the bolt group is post processed. The radius is defined in the parent bolt group object and plotted as a purple circle at the bolt shaft mid.

rslip

For the slip evaluation to work the bolts must have pretension and the contacts must be frictional so that the contact friction stress is concentrated around the bolts as in the figure above.

Use contact behavior “Asymmetric” instead of “Program Controlled” (auto asymmetric) to speed up post processing. Otherwise, there is an extra deactivated contact pair with zero result for every active pair.

Bonded contacts may be used only if creating imprints in the contact faces around each bolt and exclude the areas outside the imprint from the contact.

Before evaluating the bolt result verify that the Contact Slip Radius circles do not overlap each other. The resulting contact force extraction will then be erroneous since a to large area is included when summing the force around each bolt (left figure below). Reduce the Contact Slip radius until they just touch before evaluating. rslip2

When the model is solved the Contact Slip radius can be changed without needing to re-solve the analysis but the cached bolt result file must be deleted manually. Right-click on the corresponding Bolt object and select the action “Clear Result File”. Clear the bolt result and evaluate it again. (The “boltRes” file is re-generated.) rslip3